At a glance

Multiparameter probe for Gecko Waterlab with IPX5 ingress rating and wide operating range (0?80 °C). Designed for the in.touch 3+ ecosystem via the CO module.

Gecko - Waterlab - Probe

Measurement Electrode - WaterLab System
0 Reviews
SKU: 12563MPN: 9960-400001 LOGIN FOR TRADE PRICING

£685.93

INC VAT
1 In Stock
Same day dispatch by 14:00
QTY
LID: 81298

Product Details

Replacement multiparameter electrode for the Gecko Waterlab monitoring system. Designed to sit in the Waterlab chamber and connect to the in.touch 3+ CO module for continuous pH/ORP/temperature monitoring. Robust build, serviceable in situ, and engineered for low-turbulence flow inside the chamber.

What it does

  • Measures water chemistry (pH, ORP and temperature) inside the controlled-flow chamber.

Compatibility (quick checks)

  • Fits the Gecko Waterlab chamber.
  • Requires in.touch 3+ (CO module with water monitoring board); not supported on in.touch 2 or in.touch 3.
  • Works with in.yt / in.ye / in.yj packs (2012+).

Install & safety

  • Power down the spa pack before handling sensors and opening the chamber.
  • Lubricate O-rings with silicone grease; hand-tighten only.
  • Rinse and calibrate per Waterlab instructions in the Gecko app.
  • Keep the sensing end wet in suitable storage solution; never store in deionised water.
Compatibility
  • Required module: in.touch 3+ (CO module with water monitoring board). Probe connects to the CO-port short cable.
  • Supported packs: in.yt / in.ye / in.yj, manufacture year 2012 or newer.
  • Not supported: in.touch 2 and in.touch 3.

Installation
  1. Insert probe into Waterlab chamber and secure per orientation guidance (system within ±5° of vertical).
  2. Connect to the CO module's short cable; verify LED status (blinking blue = normal, full red = no probe, full yellow = probe not yet identified).
  3. After startup, allow ~30 minutes for readings to stabilize once flow is established.
  4. Calibrate using Gecko app when prompted (typ. once over lifetime, ~2 years).
  5. For cleaning, follow pH/ORP electrode guidance; recondition and recalibrate after cleaning.
  6. Winterization: store wet in suitable solution; never dry; never in DI water.
  • Operating limits: 0-80 °C (32-176 °F); avoid >15 min air exposure; IPX5 ingress.
  • Integration: Plugs into the CO port short cable on the in.touch 3+ spa module; LED states on the CO module indicate probe status (blinking blue = normal, full red = no probe, full yellow = probe not yet identified/associated).
  • Calibration: Typically once over the probe's service life (~2 years of use) using reliable pH buffers, guided in the Gecko app.
  • Service: After startup, allow ~30 minutes for readings to stabilise once flow is established.

Reviews (0)

No reviews have been added yet.

Add your Review

Questions & Answers

No questions have been asked yet.

Add your Question

Related Products

Subscribe to emails to unlock your FREE GIFT

Sign up for product news and exclusive offers from Hydrospares.

Your email address will never be shared, and you can opt out at the touch of a button.